1. Power on your NOBL AIR
Your NOBL AIR comes with the battery pre-installed.
- Locate the clear plastic tab inside the NOBL AIR.
- Gently pull the plastic tab out. Do not open the shell.
- The red LED will blink, confirming the NOBL AIR is powered on.\
Once powered on, open the NOBL App to begin setup.

2. Download the NOBL App
To begin using your NOBL AIR, download theofficial “NOBL” app from your device’s app store.
Once installed, open the app to begin setup.

3. Enable Bluetooth & Location Services
Before you continue, make sure:
- Bluetooth is turned on. This is required to scan and connect to your NOBL AIR.
- Location Services are turned on. This is required for accurate
- NOBL AIR detection and location tracking.
These settings are essential for the app to work properly.

4. Open the NOBL App
Launch the app on your device to begin setup.


5. Sign Up or Login
New Users:
Tap Sign Up and follow the on-screen instructions to create your account.
Existing Users:
Tap Login and enter your credentials.


6. Home Screen Overview
After Logging In:
- If you already have a NOBL AIR connected, the top map card will show the NOBL AIR’s current location.
- If not, you will see the map card simply display your current location.

7. Add a New NOBL AIR
If no NOBL AIR is currently linked to your account, you’ll see the
Discover NOBL AIR option.
- Tap Search NOBL AIR.
- The app will begin scanning for nearby NOBL AIR Devices.
- Keep your NOBL AIR close to your phone to ensure quick and reliable detection.
- Once your NOBL AIR appears, tap it to continue.
Tip: Make sure your NOBL AIR is within Bluetooth range.



8. Name your NOBL AIR
After your NOBL AIR is detected and connected:
- You’ll be prompted to assign a name to your NOBL AIR.
- Enter the name, then tap Next.
- Tap Connect to continue. You’ll hear a beep and see the red LED blink. This confirms your NOBL AIR is successfully connected to the NOBL App.
- Your NOBL AIR will now appear in your device List.



9. Managing your NOBL AIR
Once one or more NOBL AIR devices are added:
- All NOBL AIR devices will be displayed with their names and serial numbers.
- The first NOBL AIR in your list will, by default, have its location shown on the map card.
- Tap any NOBL AIR to open a full-screen map view for a clearer and more detailed location display.


Each NOBL AIR also includes a three-dots menu on the right side,
which provides additional options such as:
- Rename the NOBL AIR.
- View the timeline.
- Unpair the NOBL AIR.
- Manage sharing and permissions (if enabled).

10. Quick Tips & Troubleshooting
Quick Tips:
- Keep your NOBL AIR within Bluetooth range during setup.
- Make sure Bluetooth and Location Services remain enabled.
- For best performance, place the NOBL AIR in the designated pocket of your suitcase. Using the keychain is optional.
Troubleshooting:
NOBL AIR not connecting?
- Make sure the plastic tab has been fully removed.
- Move the NOBL AIR closer to your phone.R
- estart the NOBL App.
NOBL AIR not updating location?
- Confirm Location Services are enabled.
- Open the app to refresh the connection.
11. Replacing the Battery
Locate the Side Gap:
Hold the NOBL AIR and inspect the edges. You’ll find a small notch or gap on one side this is the designated opening point.
Open the Case Carefully:
The NOBL AIR is tightly sealed and may not open easily by hand.
- Use a plastic pry tool or spudger. Do not use sharp tools, as they may damage the battery or internal components.
- Insert the tip into the side gap and gently twist or pry until the cover begins to loosen.
- Once the edge lifts slightly, use your fingers to slowly peel the top cover away.
- The two halves should then snap apart completely.
If the PCB Pops Out:
Re-seat the PCB into the NOBL AIR housing half by aligning the three PCB holes with the three plastic pins inside the case. Press gently until the PCB sits securely in place. Then place the other housing half on top, align the edges, and press firmly around the perimeter until it clicks and the case is fully closed.
Insert the Battery:
Remove the old battery and insert a new CR2032 battery into the compartment with the positive (+) side facing up. The red LED will blink to confirm the NOBL AIR is powered on. When a new battery is inserted correctly, the LED will blink three times.
Battery Type: CR2032
Close the Case:
Align both housing halves and press firmly around the edges until you hear or feel a click. This confirms the NOBL AIR is securely sealed.
Note:
If the battery is inserted upside down (reverse polarity), it may short-circuit and drain immediately, and the NOBL AIR may not power on. If this happens, you’ll need to replace the battery with a new one and install it correctly.
- Keep coin cell batteries out of reach of children.
- Choking hazard: Coin cell batteries can be swallowed.
- Do not ingest the battery. If swallowed, seek medical help immediately.
- Do not attempt to recharge the battery.
- Do not crush, puncture, or expose the battery to fire or water.
- Dispose of used batteries according to local regulations.